ASHRAE HFDP Exam Overview:
| Certification Vendor: | ASHRAE |
| Exam Name: | Healthcare Facility Design Professional Certification Exam |
| Exam Number: | HFDP |
| Certificate Validity Period: | 3 years |
| Exam Format: | Multiple Choice, Computer-Based |
| Real Exam Qty: | 100 |
| Exam Price: | $495 USD (members), $695 USD (non-members) |
| Available Languages: | English |
| Exam Duration: | 120 minutes |
| Passing Score: | 700 / 1000 |
| Recommended Training: | HFDP Candidate Guidebook & Exam Blueprint ASHRAE Learning Institute Courses |
| Exam Registration: | ASHRAE Certification Portal |
| Sample Questions: | ASHRAE HFDP Sample Questions |
| Exam Way: | Computer-based, in-person at test centers worldwide |
| Pre Condition: | Professional Engineer license + 2 years healthcare HVAC experience; OR Bachelor's + 5 years total, 2 years healthcare; OR Associate/Technical degree + 7 years total, 3 years healthcare; OR High School + 10 years total, 7 years healthcare |
| Official Syllabus URL: | https://www.ashrae.org/professional-development/ashrae-certification/certification-types/hfdp-healthcare-facility-design-professional-certification |
ASHRAE HFDP Exam Syllabus Topics:
| Section | Weight | Objectives |
|---|---|---|
| Medical Background Information | 13% | - Terminology - Medical Equipment - Healthcare Departments and Procedures - Contaminants and Pathogens - Water Supply Contamination Risks |
| Unique Requirements for Healthcare Facilities | 24% | - Central Plant Design and Redundancy - Integration with Medical Equipment - Infection Control Strategies - Operations and Maintenance - Testing, Adjusting, Balancing and Commissioning - Controls and Instrumentation - Fire and Life Safety - Disaster Mitigation and Recovery |
| Standards, Guidelines, and Codes for HVAC&R Design | 24% | - ASHRAE Standards (62.1, 170, 90.1, 188, etc.) - Design Guidelines and Best Practices - Regulatory and Industry Codes |
| HVAC&R System Design for Healthcare Facilities | 39% | - Pressure Control and Airflow Management - Room Design and Air Distribution - Equipment Selection and Application - Energy Efficiency and Sustainability |
ASHRAE Healthcare Facility Design Professionals Sample Questions:
1. Which of the following particles has the smallest aerodynamic diameter?
A) Indoor fungal spores
B) Virus
C) Bacteria
D) Outdoor fungal spores
2. For a Protective Environment room, the HVAC&R design shall include?
A) A general air flow pattern that moves air from the door toward the patient's bed
B) Sustained re-circulated air flow that is isolated from the rest of the facility
C) Filtered supply air placed approximately over the patient's bed
D) Return air registers placed high on the wall directly across from the room entrance
3. In accordance with ASHRAE Standard 170, general hospital Operating Rooms must have a minimum of two return grilles, one of which must be located:
A) High, and the other low
B) At breathing height
C) As far away from the other as practical
D) Adjacent to the anesthetizing location
4. In accordance with ASHRAE Standard 170, what is the MINIMUM outdoor air change rate for a patient room in a nursing unit?
A) 12 ACH
B) 2 ACH
C) 4 ACH
D) 6 ACH
5. Which of the following combinations in an HVAC system increases the risk for the spread of healthcare- associated environmental pathogens?
A) Accumulation of dust and moisture
B) Accumulation of dust and outdoor fungi
C) Stagnant air and moisture
D) Stagnant air and outdoor fungi
Solutions:
| Question # 1 Answer: B | Question # 2 Answer: C | Question # 3 Answer: A | Question # 4 Answer: B | Question # 5 Answer: A |
We're so confident of our products that we provide no hassle product exchange.


By Madeline